Within the industrial machinery, an accurate set of feedback primarily relies on the encoder itself. Likewise, the cable carrying the respective encoder signal plays an important function. Be that as it may, electrical noises coming from motors or drives or even contactors can actually interfere with the sensitive feedback signals and thus impact how a controller interprets the position and speed.
For the manufacturers who are using high-precision rotatory encoders for industrial automation, a proper set of cable shielding assists in maintaining reliable communication between the respective machine controller and encoder. At Briter Encoder, we offer effective absolute shaft encoder solutions for the demanding set of industrial applications where a reliable set of industrial motion feedback actually matters.
Table of Contents
- Does cable shielding affect motor speed control accuracy?
- How does shielding prevent noise in industrial automation?
- Can poor shielding cause position measurement errors?
- Does shielding impact motion control signal reliability?
Does cable shielding affect motor speed control accuracy?
With Briter Encoder, developing a substantial understanding of the core relationship between the pertinent signal quality and motor feedback can thus proactively assist you in building a reliable control system. An incremental encoder produces electrical pulses as the shaft rotates.
When an unwanted level of electromagnetic interference enters the respective signal cable, the controller may actively receive distorted or even unexpected signals. With the pertinent dependence on the core severity of the interference and application, such a level of disturbance can have an influence on the feedback that is utilized for regulation of speed.
For a corresponding incremental shaft encoder for motor speed control, a shielded cable can thus offer a crucial part of the overall process of installation. The shielding actively creates a conductive barrier all around the signal conductors and thus assists in reducing the impact of the surrounding electrical noise.
At Briter Encoder, our solutions are thus intended for industrial ecologies where consistent levels of feedback assist in controlled sets of machine operation.
Also Read: Applications of Incremental Shaft Encoders in Industry 4.0 to Use
How does shielding prevent noise in industrial automation?
At Briter Encoder, we actively assist manufacturers in addressing signal reliability through consideration of the encoder along with the installation ecology altogether. Likewise, shielding does not have the power to magically eliminate each and every form of interference. Thus, instead, a conductive layer around the signal wire assists in reducing electromagnetic coupling from nearby sources.
In an industrial automation ecology, common levels of sources of electrical interference can thus include:
- Variable level of frequency motor drives and inverters
- Higher current motors and power cables
- Switching equipment along with electrical contactors
- Relays backed by other rapidly switching devices
- Power which is being poorly separated and signal wiring
Likewise, a properly shielded cable can actively assist in protecting the low-level encoder signal from these respective sources. The ultimate result drives a much cleaner connection between the rotary position sensor and the core controller of the machine.
Installation is still of crucial importance. Signal performance can, however, be affected by the respective way in which the cables are being routed in the ground, along with the pertinent quality of connectors, the subsequent length of the cables, and even electrical ecology around the cables. Likewise, shielding should not thus be considered a core catch-all solution.
Among the precision machinery, this care in installation can be of significance in ensuring consistency in feedback.
Can poor shielding cause position measurement errors?
When the machine has poor positioning performance, Briter Encoder suggests considering the whole feedback path. While accurate signals can be generated by an encoder, the signals can be affected by the amount of interference that occurs between the encoder and the controller.
Likewise, in the corresponding case of the machine motion applications, in line with the industrial encoder for machine motion control, precise positioning along with high accuracy of machines is crucial to the application. However, an unreliable set of feedback can actually be a big issue. Likewise, a stable encoder feedback for repeated operation may actually be necessary for applications, which thereby include stages, conveyors, and even robotic mechanisms.
Here are some of the following warning signs for signal interference, which are listed below:
- Irregular speed feedback
- Intermittent encoder signals
- Unexplained counting errors
- Unexpected position readings
- Unusual movement by the machine that is not recorded as feedback
Simply having the symptoms does not necessarily indicate that the problem is caused by cable shielding. Other factors can include mechanical alignment, coupling issues, encoder settings, wiring issues, electrical grounding, and controller configuration.
Thus, a systematized inspection serves a higher benefit than replacing the components without actively determining the issue. Thus, before actively determining the corrective action, reviewing the cable routing, connectors, and power wiring is crucial.
Does shielding impact motion control signal reliability?
At Briter Encoder, we identify that dependable feedback is especially crucial when the machinery actually needs repeatable movement. Be that as it may, a high-resolution shaft encoder for precision machinery can offer a detailed level of rotational feedback, but the controller still needs to receive that feedback in a correct manner.
The reliability of the signal is dependent on the system as a whole. Consideration must be given to the resolution, output type, cable construction, electrical environment, compatibility of the controller, installation method, and grounding arrangement of the encoder.
A shielded level of cable can assist this system by reducing the exposure to electromagnetic interference. However, choosing the accurate encoder and cable combination is equally significant. Likewise, engineers should actively verify key factors such as the respective output configuration, resolution, and even operating ecology and cable needs before the installation.
At Briter Encoder, we offer various encoder solutions for industrial use, and customers are able to choose the required product as per the requirements of their industrial machine or equipment.
Ready to Get Precision-Ready Encoder Feedback
Don’t skimp on an overlooked signal cable when it affects the feedback system in your machine. During the design of automation equipment, take the whole automatic loop in mind, including the encoder, cable, installation method, electrical environment, and the controller.
Contact Briter Encoder and browse through a range of encoder solutions. Find an appropriate solution for your application and use the technical team to assist you in finding the right solution if required for your machine requirements.
FAQs
- When is it better to replace than repair an encoder?
An encoder may be replaced because it has suffered damage to its mechanical parts, internal electronic failure, too much wear on rings, or other defects that cannot be fixed economically. Before replacing the encoder, technicians must ensure that the power supply, wiring, controller input, and mechanical coupling have been checked and that there are no other external causes. - What are the key considerations when choosing an encoder?
When choosing the encoder, it is essential to take into consideration the requirements imposed by the application. Pay special attention to the resolution, rotational speed, type of shaft, degree of environmental protection, type of signals, mounting space, operating temperature, and controller interface. - How can encoder maintenance help increase encoder work performance?
Regular maintenance of the encoder will help to detect fallen bolts, broken cables, problems related to the connectors, contamination, and problems with coupling before they become bigger defects. Clean and properly working connections will ensure smooth performance of the encoder throughout its working life.